Mic Archive
sE V7 X
Photo: sE Electronics, from its manual, p. 1.

sE Electronics

sE V7 X

Supercardioid dynamic instrument mic

Type
Dynamic
Pattern
Supercardioid
Sensitivity
−54 dBV/Pa
Impedance
300 Ω
Rated range
30 – 19k Hz

Frequency response

Angle
Distance

Frequency response: from the manual, p. 4. At 5 cm (2 in.), as printed on the graph. Anechoic or not, smoothing and typical-vs-individual are not stated.

Dashed: outside the rated range, or simulated (other angles and distances). Hover or tap the graphs for values.

Polar pattern

Polar pattern: from the manual, p. 4. Two halves: 125 Hz to 1 kHz on the left, 2 to 16 kHz on the right; 0° at the top, 5 dB per ring. Measuring conditions not stated.

Compare with other mics

All specs

From the manual
Capsuledynamic, aluminium voice coil, neodymium magnetp. 3
Sensitivity−54 dBV/Pa (2 mV/Pa). "2.0 mV/Pa (-54 dBV)". Frequency and load not stated.
Output impedance300 ohm. "Electrical Impedance".
Rated load impedance1000 ohm, more than. "Recommended Load Impedance >1K Ohms".
Rated frequency range30 Hz to 19 kHz. "Frequency Range"; tolerance not stated.
ConnectorXLR-3 male. "3-pin male XLR connector"; gold-plated contacts (page 2).
Weight269 g. 9.49 oz.
Dimensions176 × 47 mm. Length × diameter.
Supplied accessoriesMicrophone stand clip; Thread adapter; Black windscreen; Pouchp. 2
Voice coilAluminump. 3
MagnetNeodymium
ConstructionAll-metal body, stainless spring steel mesh grille, gold-plated XLR contacts; red internal windscreen against wind noisep. 2
Handling noisePatented capsule suspension, against handling noise, footfall noise and rumble

Documents

Copies kept by Mic Archive, because manufacturers move and drop their documents. Each is © sE Electronics, unchanged, with its original address.