Mic Archive
sE V7
Photo: sE Electronics, from its manual, p. 1.

sE Electronics

sE V7

Handheld supercardioid dynamic vocal mic

Approximate Some readings for this mic are uncertain; see the graphs.

Type
Dynamic
Pattern
Supercardioid
Sensitivity
−54 dBV/Pa
Impedance
300 Ω
Rated range
40 – 19k Hz

Frequency response

Angle
Distance

Frequency response: from the manual, p. 4. At 5 cm (2 in.), as printed on the graph. Distance printed on the graph. Anechoic or not, smoothing and typical-vs-individual are not stated.

Dashed: outside the rated range, or simulated (other angles and distances). Hover or tap the graphs for values.

Polar pattern

Polar pattern: from the manual, p. 4. Two halves: 125 Hz to 1 kHz on the left, 2 to 16 kHz on the right; 0° at the top, 5 dB per ring, -25 dB at the inner circle. Measuring conditions not stated. Approximate reading error up to about 1.5 dB.

Compare with other mics

All specs

From the manual
Capsuledynamic, aluminium voice coil, neodymium magnetp. 3
Sensitivity−54 dBV/Pa (2 mV/Pa). "2.0 mV/Pa -54 dBV". Frequency and load not stated.
Output impedance300 ohm. "Electrical Impedance".
Rated frequency range40 Hz to 19 kHz. "Frequency range"; tolerance not stated.
ConnectorXLR-3 male. "3-pin male XLR connector"; gold-plated contacts (page 2).
Weight305 g. 10.8 oz.
Dimensions184 × 54 mm. Length × diameter.
Supplied accessoriesMicrophone stand clip; Thread adapter; Black internal windscreen; Pouchp. 2
Voice coilAluminump. 3
MagnetNeodymium
ConstructionAll-metal body, stainless spring steel mesh grille, gold-plated XLR contacts; red internal windscreen against wind noise and plosivesp. 2
Handling noisePatented capsule suspension, against handling noise, footfall noise and rumble

Documents

Copies kept by Mic Archive, because manufacturers move and drop their documents. Each is © sE Electronics, unchanged, with its original address.

Recommended for

Instruments whose sources name this mic, or an earlier version or variant of it.