Mic Archive
TELEFUNKEN M82
Photo: TELEFUNKEN Elektroakustik, from its manual, p. 5.

TELEFUNKEN Elektroakustik

TELEFUNKEN M82

Large-diaphragm dynamic (moving coil), cardioid, for kick drum and broadcast voice, with two EQ switches; end-address

Type
Dynamic
Pattern
Cardioid
Sensitivity
−54.7 dBV/Pa computed
Max SPL
146 dB SPL
Impedance
250 Ω
Rated range
25 – 18k Hz

Frequency response

Angle
Distance

Frequency response: from the manual 2024 03, p. 5. Audio Precision plot, "RMS Level -> Normalize (dB)": normalised to 0 dB at 1 kHz. Distance, room and smoothing not stated.

Dashed: outside the rated range, or simulated (other angles and distances). Hover or tap the graphs for values.

Compare with other mics

All specs

From the manual
Capsule32 mm dynamic moving coil. "large dynamic diaphragm".p. 5
Sensitivity−54.7 dBV/Pa (1.85 mV/Pa). Not stated by the manufacturer: Stated as 1.85 mV/Pa; converted: 20·log10(0.00185) = -54.7. The product page adds "±1 dB".
Max SPL146 dB SPL, 1% THD. "Maximum SPL (for 1% THD): 146 dB".
Output impedance250 ohm, output impedance
Rated frequency range25 Hz to 18 kHz, ±3 dB. "Frequency Range: 25 Hz – 18 kHz, ± 3 dB".
Switcheskick EQ: off, on; high boost: off, on. "KICK EQ" and "HIGH BOOST" switch independently: "four distinct EQ curves".
ConnectorXLR. The XLR connector is held in the body by a recessed set screw.p. 7
Weight434 gp. 5
Dimensions63 × 155 mm. "155 mm L x 63 mm Dia": diameter × length.
Supplied accessoriesM 782 stand mount; SGMC-5R 5 m right-angle XLR cable; ZB82 zipper bag. Included accessories table; the M82 Podcast set adds the M 788 podcast arm.p. 2
Kick EQ-6 dB at 350 Hz: a low-midrange notch that "removes the boxy character of the kick drum"p. 5
High boost+6 dB at 6 kHz to 10 kHz: a slow rising shelf from about 2 kHz, 6 dB up at 10 kHz
Recommended settingsBoth off: vocals, clean guitar, brass and woodwind. High boost: broadcast voice, distorted guitar amps, mallet percussion. Kick EQ: vintage kick, bass cab, Leslie bottom. Both on: modern kick, toms, kick with resonant head
AssemblyHand-assembled and tested in TELEFUNKEN's American facility
From the product page
Sensitivity tolerance±1 dB

Documents

Copies kept by Mic Archive, because manufacturers move and drop their documents. Each is © TELEFUNKEN Elektroakustik, unchanged, with its original address.

Recommended for

Instruments whose sources name this mic, or an earlier version or variant of it.

Other mics